DIAGNOSTICS OF TUMOURS OF OVARIES AND UTERUS USING REMOTE RADIATION THERMOMETRY

The subject of the given research is the use of remote radiation thermometry while diagnosing (including differential diagnostics) tumours of ovaries аnd uterus. Here is used the method of estimating the heat flow from ovaries/uterus projection area. Before starting the study the patients are requested to get undressed for body to be accomodated to room temperature (20–22 °C) for 20 minutes. Then there is registered the head current of radiation of thermal emission of ovaries/ uterus onto the skin surface with setting of the test back ground in the iliac bone area. The patients are injected 20 ml of 40 % glucose intraveniously. The thermal currents in above-mentioned areas are taken in 40–45 minutes within 20 minutes. The type of injury is determined by irregular unfading vibrations. It is a simple additional method in differential diagnostics of tumours.